modbus_tcp collector

modbus_tcp collector performs Modbus TCP requests to collect performance data.

Configuration

Parameter Type Default Description
id String Collector's ID. Must be unique per agent instance. Will be returned along with the metrics.
type String Must be modbus_tcp
service String Equal to id Service id for output metrics
interval Integer Repetition interval in seconds
labels Array of Strings List of additional labels. Will be returned along with metrics
address String IP address of Modbus TCP server
port Integer Port of Modbus TCP server
register Integer Starting register of modbus request, zero-based
register_type String holding Modbus request type. Either holding, input or coil
format String Expected response format. See Response format for details
timeout_ms Integer 5000 Request timeout, ms.
slave Integer 255 Optional slave id, see note below.

Check address notation

Take note the starting register address is zero-based, while vendors can document the registers starting from 1. Refer to the vendor documentation and subtract 1 when necessary.

On Slave ID

Modbus TCP specification insists on using slave id of 255 for TCP connections. Meanwhile shome implmenetations await broadcast id (0). Modbust TCP-to-RTU proxies also may expect explicit slave id to process the request.

Collected Metrics

Metric Metric Type Platform Description
ts All ISO 8601 Timestamp
collector All Collector Id
labels All List of labels
value All Measured value

Compilation Features

Enable modbus_tcp feature during compiling the agent (Enabled by default).